HEPHAIS 128 2 Loops Addressable Panel
Main characteristics
2 loops (128 addr./loop) or 4 open circuits (32
det./line)
99 zones, 99 groups of command
1000 memory events
Pre-alarm mode, day/night mode
Manual/automatic activation of sounders line
2 programmable inputs + 5 programmable relay
outputs
Very easy to program and install
Self-learning of detectors on the loop
Programmable by keyboard or software
downloading/uploading
4 lines, 40 characters LCD display
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
2 loops (128 addr./loop) or 4 open circuits (32
det./line)
99 zones, 99 groups of command
1000 memory events
Pre-alarm mode, day/night mode
Manual/automatic activation of sounders line
2 programmable inputs + 5 programmable relay
outputs
Very easy to program and install
Self-learning of detectors on the loop
Programmable by keyboard or software
downloading/uploading
4 lines, 40 characters LCD display
Electrical specification
Mains supply voltage: 230Vac (-15%, +10%), 50Hz (±10%)
Operating voltage 24Vdc
Wiring: 2 x 1mm² min, shielded / Length = 2000m max
Batteries: 2 sealed lead-acid batteries connected in series 12V / 7Ah
Autonomy without mains 24 hours in standby mode and 30 minutes in alarm Autonomy for data storage out of voltage: > 7 days
Data storage: Non volatile memory (Eeprom)
Maximum current supplied: 1.2A
Mechanical characteristics
Dimensions (mm) / weight (without batteries): H x W x D = 300 x 370 x 120 / 3 Kg
Material/colour: ABS 5V/RAL 7016
IP rating: 31
Climatic characteristics
Operating temperature/storage temperature: -10°C to 50°C/+10°C to 50°C
Operating relative humidity/storage relative humidity: 93% R.H./ 80% R.H.
Inputs/outputs
Number of points/zones: 128/99
Fire detection lines: 2 loops or 4 open lines
Fire alarm management: Alarm, pre alarm, alarm confirmation, hours management day / night mode
Memory events: Up to 1000 events with date and hours
Fire alarm output: 1 alarm NC/NO free contact relay
General fault output: 1 fault NC/NO free contact relay (active in standby state)
Programmable outputs: Optionally 7 (R7P2) or 12 (R12P2) programmable free potential or resistive relays
boards (alarm, pre alarm, fault, panel signalizations/events)
Programmable inputs: 2 x inputs for external event management commanded by NO or NC contact
(activation/deactivation sounders line, reset, fault, power supply fault, technical input)
Serial communication ports: 2 RS232 communication ports for external printer/remote control panel and for
programming of the panel from the PC
Monitored sounders line: 1 x 24V/1A (shared with 24Vdc output)
External power supply: output 1 x 24V/400mA (shared with sounders line)
Description
HEPHAIS 128 is an interactive fire detection panel. Complying with EN54-2 and EN54-4 standards, HEPHAIS 128 is reliable and easy to use equipment. Associated to interactive 05 detectors range, HEPHAIS 128 constitutes the ideal fire alarm compact system. Providing as well 4 open lines or 2 loop lines, it is adapted to all types of required topologies and can manage up to 128 devices (detectors, manual call points, modules). Adapted to a large scale of application, HEPHAIS 128 can answer to requirements of buildings like hotels, retiring houses, schools, but also small industries and manufactures, storage houses, office buildings, back office centres, etc, thanks to its various and numerous outputs allowing many signalling and command orders.
Field configuration, self learning or manual setting constitute very useful start up modes which make HEPHAIS 128 installation a quick and sure operation. The software TELEHEPHAIS128 (upload/download data) permits to configure advanced functionalities and manages all the capacities of the panel up to 99 zones and 99 groups of command.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “HEPHAIS 128 2 Loops Addressable Panel” Cancel reply
Related Products
-
0 out of 5
Addressable manual call point DMA05
Main characteristics
CE certified according to CPD
Conform with the standards EN54-11, EN54-17, EN54-18
Key for reset
Separate key for test
No break glass
BA9S Waterproof IP65 version -
0 out of 5
Conventional Smoke Detector (SD3) OC05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
12V version -
0 out of 5
Conventional MCP GFE-MCPE
GFE-MCPE
Conventional Manual Call PointThe GFE-MCPE-C is a Conventional Manual Call Point, designed and manufactured to comply with EN54-11,
compatible with all GFE Conventional Control panels. A bi-colour LED flashes Green when the unit is connected to a
control panel and is illuminated Red when in Alarm.
The unit is supplied complete with a hinged flap which protects the trigger element from accidental activation and
reduces malicious activations as two actions are required in order to activate the device. This unit can be both
surface and flush mounted and it can be easily reset using the supplied key after activation. -
You've just added this product to the cart:
Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
0 out of 5Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
• Intuitive and stunning UI designed with the most popular and internationalized factor.
• Interface operation adopts modularized hierarchical design. Simpler, Better and More logical.
• Faster matching speed: Less than 1 second.Enhanced Features and Performance
• User validity settings.
• Data backup and retreival.
• Advanced User ID consisted of letters and numbers.• Chip encryption for firmware protection.
• More flexible menu configuration: double line text display.
• External printer for attendance records output (Optional).
• Optional integrated Wi-Fi\GPRS.
• Relay contacts for alarm, bell, lock, exit, switch, etc.Excellent Expand-ability
- Easy to extend functions and customize customers demand.
- For Wiegand-in, Wiegand-out, door lock connection, alarm, and bell.
-
0 out of 5
Honeywell Gent Conventional Sounder CWSO-RR-S1
- Simple, Fast, Flexible Installation
- Modern design eliminates need for device orientation.
- Designed with full range of common fixing centers.
- Approved to EN54-3.
- Superior sound output and low current consumption.
- 32 tones all approved to EN54-3.
- Suitable for wall and ceiling mount applications.
- Optimised for 12V and 24V systems
- Environmental: RoHS, WEEE
Reviews