Fire Alarm System
  • You've just added this product to the cart:

    Honeywell Gent Conventional Control Panel: 13270-02LB

    0 out of 5

    Honeywell Gent Conventional Control Panel: 13270-02LB

    • Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable
    • Device options include a full range of smoke detectors (optical, beam and duct types),
      heat detectors (fi xed temperature or rate of rise types), sounders, strobes and bells
    • Sounder options include shallow base, deep base and bedhead sounder types
    • For installations where a high degree of weatherproofi ng is required, IP55 rated
      sounders, sirens and bells are available
    • Common accessories such as manual call
      points door release units and Xenon flashers can all be accommodated
    • False alarm verification feature to filter out false alarms is selectable through software
  • You've just added this product to the cart:

    Honeywell Gent Conventional Heat Detector : Eco 1005

    0 out of 5

    Honeywell Gent Conventional Heat Detector : Eco 1005

    • Low current draw, Low profile design
    • 580C operating temperature
    • Operates at 12 and 24VDC
    • Remote alarm test feature
    • Easy Maintenance
    • Range of detector bases available
    • Remote LED Option
    • Approved to EN54 –5:2000 Class A1R
    • Approved to MED 96/98/EC (Amendment 2009/26/EC)
    • Extended warranty

  • You've just added this product to the cart:

    Honeywell Gent Conventional MCP

    0 out of 5

    Honeywell Gent Conventional MCP

    • Fully compliant with EN54, Part 11
    • Re-settable operating element option
    • Weather proof IP67
    • Semi-flush or surface mounting
    • 470 Ohm resistor and Normally Open
      contact complete with glass
    • Resistive and clean contact connections
    • Standard MCP, surface mounted
  • You've just added this product to the cart:

    Honeywell Gent Conventional Smoke Detector : Eco 1003

    0 out of 5

    Honeywell Gent Conventional Smoke Detector : Eco 1003

    F E A T U R E S

    • Photo-thermal model
    • Laser-based remote test unit
    • EN 54 Certified (2000 edition)
    • Photoelectric, photo-thermal and thermal detectors
    • Improved chamber design
    • Compatible with fire and security systems
    • -20 to +60ºC operating temperature range
    • Choice of bases (including a 12V relay version)
    • Photoelectric model with integral piezoelectric sounder
      (availability subject to further announcement)
  • You've just added this product to the cart:

    Honeywell Gent Conventional Sounder CWSO-RR-S1

    0 out of 5

    Honeywell Gent Conventional Sounder CWSO-RR-S1

    • Simple, Fast, Flexible Installation
    • Modern design eliminates need for device orientation.
    • Designed with full range of common fixing centers.
    • Approved to EN54-3.
    • Superior sound output and low current consumption.
    • 32 tones all approved to EN54-3.
    • Suitable for wall and ceiling mount applications.
    • Optimised for 12V and 24V systems
    • Environmental: RoHS, WEEE
  • You've just added this product to the cart:

    Standard 2-8 Zone Conventional Fire Alarm Panel-C-tech

    0 out of 5

    Standard 2-8 Zone Conventional Fire Alarm Panel-C-tech

    • Third-party certified to EN54 parts 2 and 4 by the Loss Prevention Certification Board (LPCB) with optional EN54 part 13. compliance from the BSI.
    • Intuitive user-friendly interface with colour-coded buttons and combined keypad/keyswitch entry.
    • Manufactured by C-TEC in the UK.
    • Two detector zone circuits.
    • Four conventional sounder circuits*
    • Integral 1.5A EN54-4/A2 compliant switch mode PSU.
    • Wide range of engineering functions including zone test, coincidence, zone delay and non-latching zones.
    • Two on-board relays (Fire and Fault).
    • Two open-collector outputs (Remote and Reset).
    • ‘Class change’ and alert inputs.
    • Installer-friendly design.
    • Attractive flush or surface mountable plastic lid and enclosure – no bezel required.
    • Low 25mA quiescent current.
    • Multiple indicators.
    • System expansion connections provided for up to eight two-wire repeaters (one CFP761 network card required per system), optional CFP relay boards and optional EN54-13 compliant sounder circuit boards.
    • Space for two x 12V 3.3Ah VRLA batteries.
    • Fully compatible with C-TEC’s ActiV range of conventional fire detectors.