Addressable smoke detector (SD3) OA05
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
8 levels sensitivity setting (0,1 dB/m to 0,35
dB/m)
Base isolator (option)
Base relay (option)
Constant sensitivity thanks to auto correction
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
Photoelectric scattering (Tyndall effect)
1 remote alarm indicator output
Lockable
Standard EN54-7
Cable section max 2,5mm²
8 levels sensitivity setting (0,1 dB/m to 0,35
dB/m)
Base isolator (option)
Base relay (option)
Constant sensitivity thanks to auto correction
Power supply specification
Main supply voltage: 12Vdc to 28 Vdc
Nominal main supply voltage: 24 Vdc
Quiescent current (24 Vdc): 140µA without base isolator / 240µA with base isolator
Alarm current (24 Vdc): 5mA ± 1mA
Fault current (24 Vdc): 140µA
Remote alarm indicator output: Individual command: 5mA ± 1mA
Mechanical characteristics
Unit weight: 130g
Unit dimensions (in mm): H:55 D:104
IP index: IP 32
Unit row material: ABS
Unit colour: White
Mounting mode: Base
Fixing - distance between centres: 50mm to 60mm
under ceiling: 2 screws Ø 4
Climatic characteristics
Operating temperature: -30°C to +60°C
Storage temperature: +10°C to +50°C
Operating relative humidity: ≤ 93%
Storage relative humidity: ≤ 85%
Description
Standard EN54-7 Ed2000
Security addressing
CE certified according to CPD
The Optical smoke detector analyzes an atmosphere by reflection of a light on the particles of smoke
according to TYNDALL effect. It detects especially the cold and visible smoke particles (0,3µm to 2µm)
produced in the early stages of a fire. The threshold of response of alarm is regulated to obtain the value
m=0,2db/m±0,03 according to standard EN54-7.
OA05 includes a developed technology (microprocessors, smd components) which means precision and
high reliability. A specific head detection fixed by a single ceiling base.
OA05 is dedicated to interactive fire detection panels.
The smoke detector OA05 is designed to be installed under flat ceiling with heights ranging between 2,5 m
and 12 m and this, in healthy and more or less ventilated buildings.
The maximum supervised surface is 80m² by detector; however it is preferable to refer to the local rules of
installation recommended in particular when the characteristics of the installation differ from those stated
above. Eight levels of sensitivity are available while programming the fire detection panel (from 0,1dB/m to
0,35 dB/m).
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Addressable smoke detector (SD3) OA05” Cancel reply
Related Products
-
0 out of 5
Conventional heat detectors TS/TR
Main characteristics
Static / Elevation of T°
Lockable
Standard EN54-5
1 remote alarm indicator output
Cable section max 2,5mm² -
0 out of 5
Honeywell Gent Conventional Control Panel: 13270-02LB
- Xenex deploys devices on conventional radial wiring layouts using standard 2-core cable
- Device options include a full range of smoke detectors (optical, beam and duct types),
heat detectors (fi xed temperature or rate of rise types), sounders, strobes and bells - Sounder options include shallow base, deep base and bedhead sounder types
- For installations where a high degree of weatherproofi ng is required, IP55 rated
sounders, sirens and bells are available - Common accessories such as manual call
points door release units and Xenon flashers can all be accommodated - False alarm verification feature to filter out false alarms is selectable through software
-
You've just added this product to the cart:
Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
0 out of 5Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
• Intuitive and stunning UI designed with the most popular and internationalized factor.
• Interface operation adopts modularized hierarchical design. Simpler, Better and More logical.
• Faster matching speed: Less than 1 second.Enhanced Features and Performance
• User validity settings.
• Data backup and retreival.
• Advanced User ID consisted of letters and numbers.• Chip encryption for firmware protection.
• More flexible menu configuration: double line text display.
• External printer for attendance records output (Optional).
• Optional integrated Wi-Fi\GPRS.
• Relay contacts for alarm, bell, lock, exit, switch, etc.Excellent Expand-ability
- Easy to extend functions and customize customers demand.
- For Wiegand-in, Wiegand-out, door lock connection, alarm, and bell.
-
0 out of 5
Honeywell Gent Conventional MCP
- Fully compliant with EN54, Part 11
- Re-settable operating element option
- Weather proof IP67
- Semi-flush or surface mounting
- 470 Ohm resistor and Normally Open
contact complete with glass - Resistive and clean contact connections
- Standard MCP, surface mounted
-
0 out of 5
Addressable manual call point DMA05
Main characteristics
CE certified according to CPD
Conform with the standards EN54-11, EN54-17, EN54-18
Key for reset
Separate key for test
No break glass
BA9S Waterproof IP65 version
Reviews
There are no reviews yet.