HEPHAIS 128 2 Loops Addressable Panel
Main characteristics
2 loops (128 addr./loop) or 4 open circuits (32
det./line)
99 zones, 99 groups of command
1000 memory events
Pre-alarm mode, day/night mode
Manual/automatic activation of sounders line
2 programmable inputs + 5 programmable relay
outputs
Very easy to program and install
Self-learning of detectors on the loop
Programmable by keyboard or software
downloading/uploading
4 lines, 40 characters LCD display
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
2 loops (128 addr./loop) or 4 open circuits (32
det./line)
99 zones, 99 groups of command
1000 memory events
Pre-alarm mode, day/night mode
Manual/automatic activation of sounders line
2 programmable inputs + 5 programmable relay
outputs
Very easy to program and install
Self-learning of detectors on the loop
Programmable by keyboard or software
downloading/uploading
4 lines, 40 characters LCD display
Electrical specification
Mains supply voltage: 230Vac (-15%, +10%), 50Hz (±10%)
Operating voltage 24Vdc
Wiring: 2 x 1mm² min, shielded / Length = 2000m max
Batteries: 2 sealed lead-acid batteries connected in series 12V / 7Ah
Autonomy without mains 24 hours in standby mode and 30 minutes in alarm Autonomy for data storage out of voltage: > 7 days
Data storage: Non volatile memory (Eeprom)
Maximum current supplied: 1.2A
Mechanical characteristics
Dimensions (mm) / weight (without batteries): H x W x D = 300 x 370 x 120 / 3 Kg
Material/colour: ABS 5V/RAL 7016
IP rating: 31
Climatic characteristics
Operating temperature/storage temperature: -10°C to 50°C/+10°C to 50°C
Operating relative humidity/storage relative humidity: 93% R.H./ 80% R.H.
Inputs/outputs
Number of points/zones: 128/99
Fire detection lines: 2 loops or 4 open lines
Fire alarm management: Alarm, pre alarm, alarm confirmation, hours management day / night mode
Memory events: Up to 1000 events with date and hours
Fire alarm output: 1 alarm NC/NO free contact relay
General fault output: 1 fault NC/NO free contact relay (active in standby state)
Programmable outputs: Optionally 7 (R7P2) or 12 (R12P2) programmable free potential or resistive relays
boards (alarm, pre alarm, fault, panel signalizations/events)
Programmable inputs: 2 x inputs for external event management commanded by NO or NC contact
(activation/deactivation sounders line, reset, fault, power supply fault, technical input)
Serial communication ports: 2 RS232 communication ports for external printer/remote control panel and for
programming of the panel from the PC
Monitored sounders line: 1 x 24V/1A (shared with 24Vdc output)
External power supply: output 1 x 24V/400mA (shared with sounders line)
Description
HEPHAIS 128 is an interactive fire detection panel. Complying with EN54-2 and EN54-4 standards, HEPHAIS 128 is reliable and easy to use equipment. Associated to interactive 05 detectors range, HEPHAIS 128 constitutes the ideal fire alarm compact system. Providing as well 4 open lines or 2 loop lines, it is adapted to all types of required topologies and can manage up to 128 devices (detectors, manual call points, modules). Adapted to a large scale of application, HEPHAIS 128 can answer to requirements of buildings like hotels, retiring houses, schools, but also small industries and manufactures, storage houses, office buildings, back office centres, etc, thanks to its various and numerous outputs allowing many signalling and command orders.
Field configuration, self learning or manual setting constitute very useful start up modes which make HEPHAIS 128 installation a quick and sure operation. The software TELEHEPHAIS128 (upload/download data) permits to configure advanced functionalities and manages all the capacities of the panel up to 99 zones and 99 groups of command.
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “HEPHAIS 128 2 Loops Addressable Panel” Cancel reply
Related Products
-
0 out of 5
Conventional MCP GFE-MCPE
GFE-MCPE
Conventional Manual Call PointThe GFE-MCPE-C is a Conventional Manual Call Point, designed and manufactured to comply with EN54-11,
compatible with all GFE Conventional Control panels. A bi-colour LED flashes Green when the unit is connected to a
control panel and is illuminated Red when in Alarm.
The unit is supplied complete with a hinged flap which protects the trigger element from accidental activation and
reduces malicious activations as two actions are required in order to activate the device. This unit can be both
surface and flush mounted and it can be easily reset using the supplied key after activation. -
0 out of 5
Global Fire Conventional Panel ORION 2-4-8
- 2, 4 and 8 Zone non-expandable control panels
- Up to 32 conventional smoke and/or heat detectors per Zone
- Active End of Line monitoring
- Programmable non-latching Zones
- Delay timer programmable on/off per Zone
- Coincidence programmable for adjacent Zones
- One man test
- Supervised auxiliary 24 volt output
- 2 Supervised/ monitored sounder circuits
- 3 Remote inputs used for activation of Class Change, Day/Night mode, and Reset
- 2 Relay outputs fire and fault
- Fully EN54 part 2 and 4 compliant
- Repeater output
- Multiplexed output for LEDs and additional relay outputs per zone (GFE-MPX-REL)
- Multiplexed output for sounders per zone (GFE-MPX-SNDR)
- Addressable Loop Interface card (GFE-ADLI)
- 2 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 2
- 4 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 4
- 8 ZONES CONVENTIONAL FIRE DETECTION CONTROL PANEL: ORION 8
-
0 out of 5
Addressable Indoor sounder AVSA05R
Main characteristics
Addressable independent device
Loop powered
90 dB (+/- 3 dB) at 1 meter
6 tones selectable
Integrated loop isolator
Red or white color
Lateral hearings
Volume control -
0 out of 5
ALPHA 2 – 2 zones fire detection conventional panel
Main characteristics
2 monitored conventional lines
Maximum 32 detectors and/or manual call
points per line
Monitored sounders line
Auto powered sounders line
External power supply outputs
Programmable open collector output
Level 2 access code.
Easy management
Small size plastic box -
0 out of 5
TD-3332H2
Features
Support 8 / 16 / 32 CH 8MP / 5MP / 4MP / 3MP / 1080P / 960P / 720P IP input
Adopt standard H.265 and H.264 high profile compression format to get high-quality video at much lower bit rate
Intuitive and user-friendly Graphic User Interface ( GUI ), Windows style operation by mouse
Multi-mode recording: manual / timer / motion / sensor
Playback : 8 / 16 / 16 CH simultaneous playback
Search : time slice, time, event ( manual, sensor, motion ), tag search
Express and flexible backup via USB, network and so on
Pentaplex : preview, record, playback, backup and remote access
DHCP, DDNS, PPPoE network protocol and CMS supported
Remote control via IE or CMS : preview, playback, backup, PTZ and configuration
Dual stream technology for local storage with high definition, remote network transmission and remote surveillance with mobile device
Multi-user online simultaneously
Authorization management, log view and device status view
4K output, true high resolution display
Support PTZ preset and auto cruise, up to 255 presets and 8 cruises
Support NAT function and QRCode scanning by mobile phone and PAD
Powerful smart phone & Pad surveillance with iOS and Andriod OS
Reviews
There are no reviews yet.