HEPHAIS 128 2 Loops Addressable Panel

Main characteristics
2 loops (128 addr./loop) or 4 open circuits (32
det./line)
99 zones, 99 groups of command
1000 memory events
Pre-alarm mode, day/night mode
Manual/automatic activation of sounders line
2 programmable inputs + 5 programmable relay
outputs
Very easy to program and install
Self-learning of detectors on the loop
Programmable by keyboard or software
downloading/uploading
4 lines, 40 characters LCD display

  • Function
  • Specifications
  • Description
  • Additional information
  • Reviews (0)

Main characteristics
2 loops (128 addr./loop) or 4 open circuits (32
det./line)
99 zones, 99 groups of command
1000 memory events
Pre-alarm mode, day/night mode
Manual/automatic activation of sounders line
2 programmable inputs + 5 programmable relay
outputs
Very easy to program and install
Self-learning of detectors on the loop
Programmable by keyboard or software
downloading/uploading
4 lines, 40 characters LCD display

Electrical specification
Mains supply voltage:                                                                   230Vac (-15%, +10%), 50Hz (±10%)
Operating voltage                                                                          24Vdc
Wiring:                                                                                            2 x 1mm² min, shielded / Length = 2000m max
Batteries:                                                                                        2 sealed lead-acid batteries connected in series                                                                                                              12V / 7Ah
Autonomy without mains 24 hours in standby                                                                                                              mode and 30 minutes in alarm Autonomy for                                                                                                          data storage out of voltage:                                                        > 7 days
Data storage:                                                                                Non volatile memory (Eeprom)
Maximum current supplied:                                                     1.2A
Mechanical characteristics
Dimensions (mm) / weight (without batteries):                  H x W x D = 300 x 370 x 120 / 3 Kg
Material/colour:                                                                          ABS 5V/RAL 7016
IP rating:                                                                                       31
Climatic characteristics
Operating temperature/storage temperature:                     -10°C to 50°C/+10°C to 50°C
Operating relative humidity/storage relative humidity:    93% R.H./  80% R.H.
Inputs/outputs
Number of points/zones:                                                          128/99
Fire detection lines:                                                                    2 loops or 4 open lines
Fire alarm management:                                                           Alarm, pre alarm, alarm confirmation, hours                                                                                                                management day / night mode
Memory events:                                                                           Up to 1000 events with date and hours
Fire alarm output:                                                                       1 alarm NC/NO free contact relay
General fault output:                                                                  1 fault NC/NO free contact relay (active in                                                                                                                       standby state)
Programmable outputs:                                                             Optionally 7 (R7P2) or 12 (R12P2)                                                                                                                                     programmable free potential or resistive relays
boards (alarm, pre alarm, fault, panel                                                                                                                               signalizations/events)
Programmable inputs:                                                               2 x inputs for external event management                                                                                                                      commanded by NO or NC contact
(activation/deactivation sounders line, reset,                                                                                                                  fault, power supply fault, technical input)
Serial communication ports:                                                    2 RS232 communication ports for external                                                                                                                    printer/remote control panel and for
programming of the panel from the PC
Monitored sounders line:                                                          1 x 24V/1A (shared with 24Vdc output)
External power supply:                                                              output 1 x 24V/400mA (shared with sounders                                                                                                               line)

Description

HEPHAIS 128 is an interactive fire detection panel. Complying with EN54-2 and EN54-4 standards, HEPHAIS 128 is reliable and easy to use equipment. Associated to interactive 05 detectors range, HEPHAIS 128 constitutes the ideal fire alarm compact system. Providing as well 4 open lines or 2 loop lines, it is adapted to all types of required topologies and can manage up to 128 devices (detectors, manual call points, modules). Adapted to a large scale of application, HEPHAIS 128 can answer to requirements of buildings like hotels, retiring houses, schools, but also small industries and manufactures, storage houses, office buildings, back office centres, etc, thanks to its various and numerous outputs allowing many signalling and command orders.
Field configuration, self learning or manual setting constitute very useful start up modes which make HEPHAIS 128 installation a quick and sure operation. The software TELEHEPHAIS128 (upload/download data) permits to configure advanced functionalities and manages all the capacities of the panel up to 99 zones and 99 groups of command.

Additional information

Weight 23 kg
Dimensions 12 × 24 × 35 in
Color

Black, Green, Indigo

Size

Large, Medium, Small

Reviews

There are no reviews yet.