Addressable manual call point DMA05
Main characteristics
CE certified according to CPD
Conform with the standards EN54-11, EN54-17, EN54-18
Key for reset
Separate key for test
No break glass
BA9S Waterproof IP65 version
- Function
- Specifications
- Description
- Additional information
- Reviews (0)
Main characteristics
CE certified according to CPD
Conform with the standards EN54-11, EN54-17, EN54-18
Key for reset
Separate key for test
No break glass
BA9S Waterproof IP65 version
Power supply specification
Main supply voltage: 12V to 28Vdc
Nominal main supply voltage 24Vdc
Quiescent current 0.15 ma
Alarm current: 5mA @ 24Vdc
Mechanical characteristics
Unit weight: 170g
Unit dimensions (in mm): 99 x 98 x 49
Unit row material: ABS
Unit colour: Red
Protection class: IP33
Climatic characteristics
Operating temperature: -10°C to +60°C
Storage temperature: +10°C to +50°C
Operating relative humidity: ≤ 93%
Storage relative humidity: ≤ 85%
Description
DMA05 manual call points are devices of transmission of an alarm status towards an addressable indicating panel.
This action is carried out by the operator through mechanical pressure on the window located in the front.
Return to the normal status can be done only after local resetting using a special key.
Moreover the addressable version of manual call point integrates on every device a switch providing the function of line
isolator. This function is assured only in association with the HEPHAIS range panels which are equipped with boards
managing the loop/line. The function “Isolator of line” makes possible the isolation of sections in short-circuit (Shortcircuit
between 2 conductors of the connecting cable), located between 2 devices equipped with switch.
Usually, connection is carried out with shielded cable from 0, 6mm² to 1,5mm². Shield must be protected by an insulator
tape in order to avoid any short-circuit.
Call point also exits in waterproof IP65 version BA95S
Additional information
Weight | 23 kg |
---|---|
Dimensions | 12 × 24 × 35 in |
Color | Black, Green, Indigo |
Size | Large, Medium, Small |
Be the first to review “Addressable manual call point DMA05” Cancel reply
Related Products
-
0 out of 5
Addressable Indoor sounder AVSA05R
Main characteristics
Addressable independent device
Loop powered
90 dB (+/- 3 dB) at 1 meter
6 tones selectable
Integrated loop isolator
Red or white color
Lateral hearings
Volume control -
0 out of 5
ALPHA 2 – 2 zones fire detection conventional panel
Main characteristics
2 monitored conventional lines
Maximum 32 detectors and/or manual call
points per line
Monitored sounders line
Auto powered sounders line
External power supply outputs
Programmable open collector output
Level 2 access code.
Easy management
Small size plastic box -
0 out of 5
Conventional call point DMCL05
Main characteristics
CE certified according to CPD
Conform with the norm EN54-11
Key for reset
Separate key for test
No break glass
Red colour for Alarm status
Yellow colour for extinguishing command
Blue colour for Extinguishing abort -
You've just added this product to the cart:
Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
0 out of 5Fingerprint Time & Attendance and Access Control Terminal Model: iClock 680
• Intuitive and stunning UI designed with the most popular and internationalized factor.
• Interface operation adopts modularized hierarchical design. Simpler, Better and More logical.
• Faster matching speed: Less than 1 second.Enhanced Features and Performance
• User validity settings.
• Data backup and retreival.
• Advanced User ID consisted of letters and numbers.• Chip encryption for firmware protection.
• More flexible menu configuration: double line text display.
• External printer for attendance records output (Optional).
• Optional integrated Wi-Fi\GPRS.
• Relay contacts for alarm, bell, lock, exit, switch, etc.Excellent Expand-ability
- Easy to extend functions and customize customers demand.
- For Wiegand-in, Wiegand-out, door lock connection, alarm, and bell.
-
0 out of 5
Honeywell Gent Conventional Heat Detector : Eco 1005
• Low current draw, Low profile design
• 580C operating temperature
• Operates at 12 and 24VDC
• Remote alarm test feature
• Easy Maintenance
• Range of detector bases available
• Remote LED Option
• Approved to EN54 –5:2000 Class A1R
• Approved to MED 96/98/EC (Amendment 2009/26/EC)
• Extended warranty
Reviews